{"id":11294,"date":"2016-10-01T11:32:15","date_gmt":"2016-10-01T11:32:15","guid":{"rendered":"http:\/\/www.safetyangel.com\/recdev\/?page_id=11294"},"modified":"2016-12-05T02:22:50","modified_gmt":"2016-12-05T02:22:50","slug":"mpc","status":"publish","type":"page","link":"http:\/\/www.safetyangel.com\/recdev\/mpc\/","title":{"rendered":"MPC"},"content":{"rendered":"<div id=\"dt_row_1177727757551\" class=\"clearfix dt_row\"><div id=\"dt_column_2\" class=\"dt_column col-sm-12\"><div id=\"dt_row_3177727757588\" class=\"row dt_row\"><div id=\"dt_column_4\" class=\"dt_column col-sm-6\"><\/div><div id=\"dt_column_5\" class=\"dt_column col-sm-6\"><\/div><\/div><div id=\"dt_row_6177727757540\" class=\"row dt_row\"><div id=\"dt_column_7\" class=\"dt_column col-sm-5\"><\/div><div id=\"dt_column_8\" class=\"dt_column col-sm-7\"><\/div><\/div><\/div><\/div><div id=\"dt_row_9177727757515\" class=\"clearfix dt_row\"><div class=\"container\"><div class=\"row\"><div id=\"dt_column_10\" class=\"dt_column col-sm-12\"><div id=\"dt_row_11177727757518\" class=\"row dt_row\"><div id=\"dt_column_12\" class=\"dt_column col-sm-12\"><div id=\"dt_text13177727757537\" class=\"dt_text\">\n<h2 style=\"text-align: left; font-size: 40px; margin-bottom: 10px; color: #0093d5; font-weight: normal;\">MPC: MSG-3 Aircraft Maintenance Program Creation Software Tool<\/h2>\n<hr \/>\n<ul style=\"padding-left: 0px; margin-bottom: 5px;\">\n<li class=\"linktitle\"><a href=\"http:\/\/www.safetyangel.com\/recdev\/mpc-features-summary\/\">Features<\/a><\/li>\n<li class=\"linktitle\"><a href=\"http:\/\/www.safetyangel.com\/recdev\/update\/\">Updates<\/a><\/li>\n<li class=\"linktitle\"><a href=\"http:\/\/www.safetyangel.com\/recdev\/frequently-asked-questions-3\/\">FAQs<\/a><\/li>\n<li class=\"linktitle\"><a href=\"http:\/\/www.safetyangel.com\/recdev\/try\/\">Try<\/a><\/li>\n<li class=\"linktitle\"><a href=\"http:\/\/www.safetyangel.com\/recdev\/buy\/\">Buy<\/a><\/li>\n<\/ul>\n<hr \/>\n<p style=\"text-align: left; font-size: 16px; margin-bottom: 5px; font-weight: normal;\"><strong>An MSG-3 compliant maintenance program creator<\/strong><\/p>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><div id=\"dt_row_14177727757577\" class=\"clearfix dt_row\"><div class=\"container\"><div class=\"row\"><div id=\"dt_column_15\" class=\"dt_column col-sm-6\"><div id=\"dt_row_16177727757517\" class=\"row dt_row\"><div id=\"dt_column_17\" class=\"dt_column col-sm-12\"><div id=\"dt_text18177727757568\" class=\"dt_text\">\n<p style=\"text-align: left; font-weight: normal;\">ReliaSoft&#8217;s MPC software is an MSG-3 compliant maintenance program creator for the aircraft \/ aerospace industry. The software has been designed to assist MSG-3 working groups to perform <strong>Systems and Powerplant Analysis, Structural Analysis<\/strong> and\/or <strong>Zonal-L\/HIRF Analysis<\/strong> in accordance with the MSG-3: Operator\/Manufacturer Scheduled Maintenance Development guidelines.<\/p>\n<p style=\"text-align: left; font-weight: normal;\">MPC facilitates the analysis process, provides flexible data management capabilities and offers automated report generation in templates that have been accepted for submission to the aircraft industry maintenance review board.<\/p>\n<\/div><\/div><\/div><\/div><div id=\"dt_column_19\" class=\"dt_column col-sm-6\"><div id=\"dt_row_20177727757565\" class=\"row dt_row\"><div id=\"dt_column_21\" class=\"dt_column col-sm-12\"><div id=\"dt_image22\" class=\"dt_image\"><div class=\"image-align-center\"><a href=\"http:\/\/www.safetyangel.com\/recdev\/wp-content\/uploads\/2016\/10\/mpc_interface.png\" target=\"_self\"><img decoding=\"async\"  class=\"img-responsive style-default\" src=\"http:\/\/www.safetyangel.com\/recdev\/wp-content\/uploads\/2016\/10\/img-11.png\" alt=\"\"\/><\/a><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div id=\"dt_row_23177727757566\" class=\"clearfix dt_row\"><div id=\"dt_column_24\" class=\"dt_column col-sm-12\"><div id=\"dt_row_25177727757586\" class=\"row dt_row\"><div id=\"dt_column_26\" class=\"dt_column col-sm-6\"><div id=\"dt_row_27177727757557\" class=\"row dt_row title-blck\"><div id=\"dt_column_28\" class=\"dt_column col-sm-12\"><div id=\"dt-section-head-29\" class=\"dt-section-head center  size-custom\">\r\n              <div><h2 style=\"color:#ffffff;font-size:21px\" class=\"section-main-title\">Ready to learn more?<\/h2><\/div><\/div><\/div><\/div><\/div><div id=\"dt_column_30\" class=\"dt_column col-sm-6\"><\/div><\/div><div id=\"dt_row_31177727757567\" class=\"row dt_row\"><div id=\"dt_column_32\" class=\"dt_column col-sm-4\"><div id=\"dt_row_33177727757554\" class=\"row dt_row\"><div id=\"dt_column_34\" class=\"dt_column col-sm-12\"><div id=\"dt_text35177727757516\" class=\"dt_text\">\n<h3><span style=\"color: #0093d5; font-weight: 300;\">Software Features<\/span><\/h3>\n<p style=\"text-align: left; font-weight: normal;\">The MPC software is available in two versions:<\/p>\n<p style=\"text-align: left; font-weight: normal;\"><strong>MPC Standard<\/strong> supports the entire process for Systems and Powerplant Analysis.<\/p>\n<p style=\"text-align: left; font-weight: normal; padding-bottom: 165px;\"><strong>MPC Plus<\/strong> includes additional support for Structural Analysis and Zonal-L\/HIRF Analysis.<\/p>\n<ul style=\"font-family: Arial; font-size: 11px; font-weight: bold; line-height: 2; list-style-type: none; margin: 0px 7px 0px 0px; padding: 0px; float: right;\">\n<li style=\"border-left: 0px solid #999; display: inline; margin: 0 0px 0 0; padding: 1px; float: left;\"><a href=\"http:\/\/www.safetyangel.com\/recdev\/mpc-features-summary\/\"><span style=\"color: #0093d5;\">MPC Features Summary<\/span><\/a><\/li>\n<\/ul>\n<\/div><\/div><\/div><\/div><div id=\"dt_column_36\" class=\"dt_column col-sm-4\"><div id=\"dt_row_37177727757518\" class=\"row dt_row\"><div id=\"dt_column_38\" class=\"dt_column col-sm-12\"><div id=\"dt_text39177727757581\" class=\"dt_text\">\n<h3><span style=\"color: #0093d5; font-weight: 300;\">Synthesis Integration<\/span><\/h3>\n<p style=\"text-align: left; font-weight: normal; padding-bottom: 164px;\">With integration into the Synthesis Platform, analyses are now stored in a centralized database that supports simultaneous access by multiple users and shares relevant reliability information between Synthesis-enabled software tools. For enterprise-level repositories, both Microsoft SQL Server\u00ae and Oracle\u00ae are supported.<\/p>\n<ul style=\"font-family: Arial; font-size: 11px; font-weight: bold; line-height: 2; list-style-type: none; margin: 0px 7px 0px 0px; padding: 0px; float: right;\">\n<li style=\"border-left: 0px solid #999; display: inline; margin: 0 0px 0 0; padding: 1px; float: left;\"><a href=\"http:\/\/www.safetyangel.com\/recdev\/the-synthesis-platform\/\"><span style=\"color: #0093d5;\">The Synthesis Platform<\/span><\/a><\/li>\n<\/ul>\n<\/div><\/div><\/div><\/div><div id=\"dt_column_40\" class=\"dt_column col-sm-4\"><div id=\"dt_row_41177727757583\" class=\"row dt_row\"><div id=\"dt_column_42\" class=\"dt_column col-sm-12\"><div id=\"dt_text43177727757556\" class=\"dt_text\">\n<h3><span style=\"color: #0093d5; font-weight: 300;\">Applications and Benefits<\/span><\/h3>\n<p style=\"text-align: left; font-weight: normal;\">Some of the benefits from using the MPC software to facilitate the analysis and reporting for MSG-3 analysis include:<\/p>\n<ul style=\"font-weight: normal;\">\n<li>Guides analysts through the process to implement the MSG-3 logic.<\/li>\n<li>Provides centralized data storage that allows multiple users to cooperate on the analysis and makes it easy to reuse relevant information from prior analyses.<\/li>\n<li>Automatically generates the complete maintenance program report document in Microsoft Word\u00ae. This report can be generated in a fraction of the time required to manually prepare report documents.<\/li>\n<\/ul>\n<ul style=\"font-family: Arial; font-size: 11px; font-weight: bold; line-height: 2; list-style-type: none; margin: 0px 7px 0px 0px; padding: 0px; float: right;\">\n<li style=\"border-left: 0px solid #999; display: inline; margin: 0 0px 0 0; padding: 1px; float: left;\"><a href=\"http:\/\/www.reliasoft.com\/mpc\/samples.htm\"><span style=\"color: #0093d5;\">Sample Reports<\/span><\/a><\/li>\n<\/ul>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><div id=\"dt_row_44177727757592\" class=\"clearfix dt_row\"><div id=\"dt_column_45\" class=\"dt_column col-sm-12\"><div id=\"dt_row_46177727757595\" class=\"row dt_row\"><div id=\"dt_column_47\" class=\"dt_column col-sm-6\"><div id=\"dt_row_48177727757516\" class=\"row dt_row title-blck\"><div id=\"dt_column_49\" class=\"dt_column col-sm-12\"><div id=\"dt-section-head-50\" class=\"dt-section-head center  size-custom\">\r\n              <div><h2 style=\"color:#ffffff;font-size:21px\" class=\"section-main-title\">Software Capability Highlights<\/h2><\/div><\/div><\/div><\/div><\/div><div id=\"dt_column_51\" class=\"dt_column col-sm-6\"><\/div><\/div><\/div><\/div><div class=\"container\"><div class=\"row\"><div id=\"dt_row_52177727757556\" class=\"clearfix dt_row\"><div id=\"dt_column_53\" class=\"dt_column col-sm-12\"><div id=\"dt_row_54177727757527\" class=\"row dt_row\"><div id=\"dt_column_55\" class=\"dt_column col-sm-12\"><div id=\"dt_row_56177727757576\" class=\"row dt_row\"><div id=\"dt_column_57\" class=\"dt_column col-sm-6\"><div class=\"dt_responsive_tab\"><ul id=\"tabid_58\" class=\"nav nav-tabs responsive\"><li class=\"active\">\r\n                        <a href=\"#tabid_58_0\"><\/a>\r\n                  <\/li>\n<li>\r\n                        <a href=\"#tabid_58_1\">MSG-3 Systems and Powerplant Analysis<\/a>\r\n                  <\/li>\n<li>\r\n                        <a href=\"#tabid_58_2\">Description &amp; Operation (D&amp;O) Documents<\/a>\r\n                  <\/li>\n<li>\r\n                        <a href=\"#tabid_58_3\">MSG-3 Structural Analysis (Plus Only)<\/a>\r\n                  <\/li>\n<li>\r\n                        <a href=\"#tabid_58_4\">MSG-3 Zonal-L\/HIRF Analysis (Plus Only)<\/a>\r\n                  <\/li>\n<li>\r\n                        <a href=\"#tabid_58_5\">Automated Report Generation<\/a>\r\n                  <\/li>\n<li>\r\n                        <a href=\"#tabid_58_6\">Facilitating Team Effort<\/a>\r\n                  <\/li>\n<li>\r\n                        <a href=\"#tabid_58_7\">Data Management<\/a>\r\n                  <\/li>\n<li>\r\n                        <a href=\"#tabid_58_8\">Synthesis Integration<\/a>\r\n                  <\/li>\n<li>\r\n                        <a href=\"#tabid_58_9\">Documentation<\/a>\r\n                  <\/li>\r\n          <\/ul>\n<div class=\"tab-content responsive\">\r\n                    <div id=\"tabid_58_0\" class=\"tab-pane in active\"><\/div>\n<div id=\"tabid_58_1\" class=\"tab-pane\"><\/p>\n<ul class=\"highlights_list\">\n<li>Predefined Systems and Subsystems\n<ul class=\"highlights_list\">\n<li>Based on ATA iSpec 2200<\/li>\n<\/ul>\n<\/li>\n<li>Identify Maintenance Significant Items (MSIs)<\/li>\n<li>Functional Failure Analysis (F-F-E-C)<\/li>\n<li>Failure Effect Categorization (FEC)\n<ul class=\"highlights_list\">\n<li>Evident Safety<\/li>\n<li>Evident Operational<\/li>\n<li>Evident Economic<\/li>\n<li>Hidden Safety<\/li>\n<li>Hidden Non-Safety<\/li>\n<\/ul>\n<\/li>\n<li>Maintenance Task Selection\n<ul class=\"highlights_list\">\n<li>Lubrication (LUB) or Servicing (SVC)<\/li>\n<li>Operational Check (OPC)<\/li>\n<li>Visual Check (VCK)<\/li>\n<li>General Visual Inspection (GVI)<\/li>\n<li>Detailed Inspection (DET)<\/li>\n<li>Special Detailed Inspection (SDI)<\/li>\n<li>Scheduled Structural Health Monitoring (S-SHM)<\/li>\n<li>Functional Check (FNC)<\/li>\n<li>Restoration (RST)<\/li>\n<li>Discard (DIS)<\/li>\n<\/ul>\n<\/li>\n<li>Check MSI Analysis (highlights potential discrepancies in the application of MSG-3 logic)<\/li>\n<\/ul>\n<p><\/div>\n<div id=\"tabid_58_2\" class=\"tab-pane\"><\/p>\n<ul>\n<li>Attached to the analysis<\/li>\n<li>Integrated into report output<\/li>\n<\/ul>\n<p><\/div>\n<div id=\"tabid_58_3\" class=\"tab-pane\"><\/p>\n<ul class=\"highlights_list\">\n<li>Predefined Structures and Sub-Structures\n<ul class=\"highlights_list\">\n<li>Based on ATA iSpec 2200<\/li>\n<\/ul>\n<\/li>\n<li>Identify Structural Significant Items (SSIs)<\/li>\n<li>Configurable Rating Systems\n<ul class=\"highlights_list\">\n<li>Environmental Deterioration Analysis<\/li>\n<li>Accidental Damage Analysis<\/li>\n<li>Fatigue Damage Analysis<\/li>\n<\/ul>\n<\/li>\n<li>Structural Analysis Tasks\n<ul class=\"highlights_list\">\n<li>General Visual Inspection (GVI)<\/li>\n<li>Detailed Inspection (DET)<\/li>\n<li>Special Detailed Inspection (SDI)<\/li>\n<li>Scheduled Structural Health Monitoring (S-SHM)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><\/div>\n<div id=\"tabid_58_4\" class=\"tab-pane\"><\/p>\n<ul class=\"highlights_list\">\n<li>Predefined Major Zones\n<ul class=\"highlights_list\">\n<li>Based on ATA iSpec 2200<\/li>\n<\/ul>\n<\/li>\n<li>Logic for selecting the appropriate analysis<\/li>\n<li>\u00a0Configurable Rating Systems\n<ul class=\"highlights_list\">\n<li>Standard Zonal Analysis<\/li>\n<li>Enhanced Zonal Analysis<\/li>\n<li>L\/HIRF Analysis<\/li>\n<\/ul>\n<\/li>\n<li>Zonal Analysis Tasks\n<ul class=\"highlights_list\">\n<li>General Visual Inspection (GVI)<\/li>\n<li>Transfer &#8220;zonal candidate&#8221; tasks from other analyses<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><\/div>\n<div id=\"tabid_58_5\" class=\"tab-pane\"><\/p>\n<ul>\n<li>Microsoft Word\u00ae or Microsoft Excel\u00ae<\/li>\n<li>Easy to modify, print, PDF and distribute<\/li>\n<li>Choice of predefined templates for MSI reports (Standard, Dassault and Sukhoi)<\/li>\n<li>Customizable report templates<\/li>\n<\/ul>\n<p><\/div>\n<div id=\"tabid_58_6\" class=\"tab-pane\"><\/p>\n<ul>\n<li>Management of &#8220;Working Group Stamps&#8221;<\/li>\n<li>Option to store notes and status updates<\/li>\n<li>Option to flag portions of the analysis<\/li>\n<li>Link or attach other related files<\/li>\n<\/ul>\n<p><\/div>\n<div id=\"tabid_58_7\" class=\"tab-pane\"><\/p>\n<ul>\n<li>Import from Excel<\/li>\n<li>Cut\/Copy\/Paste or Drag &amp; Drop<\/li>\n<li>Browse and import from existing analyses<\/li>\n<li>Find and reuse existing text descriptions<\/li>\n<\/ul>\n<p><\/div>\n<div id=\"tabid_58_8\" class=\"tab-pane\"><\/p>\n<ul>\n<li>Import data from a systems and powerplant analysis into Xfmea, RCM++ or RBI<\/li>\n<\/ul>\n<p><\/div>\n<div id=\"tabid_58_9\" class=\"tab-pane\"><\/p>\n<ul>\n<li><a href=\"http:\/\/www.safetyangel.com\/recdev\/contact-page-three\/\">Detailed Online Help File<\/a><\/li>\n<li><a href=\"http:\/\/www.safetyangel.com\/recdev\/contact-page-three\/\">Print-Ready User&#8217;s Guide<\/a><\/li>\n<\/ul>\n<p><\/div><\/div>\n<\/div><script type=\"text\/javascript\">\r\njQuery(document).ready(function($){\r\n  $( '#tabid_58 a' ).click( function ( e ) {\r\n        e.preventDefault();\r\n        $( this ).tab( 'show' );\r\n  } );fakewaffle.responsiveTabs( $( '#tabid_58' ),['lg','md','sm','xs'] );});\r\n<\/script><\/div><div id=\"dt_column_59\" class=\"dt_column col-sm-6\"><div id=\"dt_text60177727757581\" class=\"dt_text\">\n<div style=\"background-color: #fff; border: 1px solid rgba(0, 0, 0, 0.45); font-size: 13px; line-height: 1.1em; box-shadow: 1px 0px 10px rgba(123, 123, 123, 0.66); padding: 16px; width: 82%; border-radius: 11px; margin: auto;\">\n<p><b>Latest Release<\/b><br \/>\n10.1.6 \u2666 24-Oct-2016 <b>| <a style=\"color: #4e93d5; font-weight: normal;\" href=\"http:\/\/www.safetyangel.com\/recdev\/update\/\">Update<\/a>\u00a0<\/b><\/p>\n<hr \/>\n<p><strong><a style=\"color: #4e93d5; font-weight: normal;\" href=\"http:\/\/www.safetyangel.com\/recdev\/contact-page-three\/\">Contact Us<\/a>\u00a0<b>| <a style=\"color: #4e93d5; font-weight: normal;\" href=\"http:\/\/www.safetyangel.com\/recdev\/contact-page-three\/\">Live Chat<\/a>\u00a0<\/b><\/strong><b>| <a style=\"color: #4e93d5; font-weight: normal;\" href=\"http:\/\/www.safetyangel.com\/recdev\/contact-page-three\/\">Technical Support<\/a>\u00a0<\/b><\/p>\n<hr \/>\n<p>Windows 7, 8, 8.1 or 10\u00a0<b><a style=\"color: #4e93d5; font-weight: normal;\" href=\"http:\/\/www.safetyangel.com\/recdev\/g400\/\">Requirements<\/a>\u00a0<\/b><\/p>\n<hr \/>\n<p><b>Interface Languages:<\/b> English<\/p>\n<hr \/>\n<p><b>Why Upgrade?<\/b><span style=\"color: #4ea0e0; font-weight: normal;\"> <a style=\"color: #4ea0e0; font-weight: normal;\" href=\"http:\/\/www.reliasoft.com\/alta\/version10.htm\">New in Version 10<\/a><\/span><\/p>\n<hr \/>\n<p><b>Pubs and Videos:<\/b><\/p>\n<ul>\n<li><span style=\"color: #4ea0e0; font-weight: normal;\"><a style=\"color: #4ea0e0;\" href=\"http:\/\/www.safetyangel.com\/recdev\/wp-content\/uploads\/2016\/10\/mpc_flyer.pdf\">2 page Flyer (*.pdf, 2.2MB)<\/a><\/span><\/li>\n<li><span style=\"color: #4ea0e0; font-weight: normal;\"><a style=\"color: #4ea0e0;\" href=\"http:\/\/www.safetyangel.com\/recdev\/wp-content\/uploads\/2016\/10\/mpc_flyer.pdf\">Synthesis Brochure (*.pdf, 8.4MB)<\/a><\/span><\/li>\n<li><span style=\"color: #4ea0e0; font-weight: normal;\"><a style=\"color: #4ea0e0;\" href=\"http:\/\/www.safetyangel.com\/recdev\/wp-content\/uploads\/2016\/10\/mpc_flyer.pdf\">Software Catalog (*.pdf, 16.3MB)<\/a><\/span><\/li>\n<\/ul>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"fullwidth.php","meta":{"footnotes":""},"class_list":["post-11294","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"http:\/\/www.safetyangel.com\/recdev\/wp-json\/wp\/v2\/pages\/11294","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.safetyangel.com\/recdev\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/www.safetyangel.com\/recdev\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/www.safetyangel.com\/recdev\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.safetyangel.com\/recdev\/wp-json\/wp\/v2\/comments?post=11294"}],"version-history":[{"count":30,"href":"http:\/\/www.safetyangel.com\/recdev\/wp-json\/wp\/v2\/pages\/11294\/revisions"}],"predecessor-version":[{"id":18180,"href":"http:\/\/www.safetyangel.com\/recdev\/wp-json\/wp\/v2\/pages\/11294\/revisions\/18180"}],"wp:attachment":[{"href":"http:\/\/www.safetyangel.com\/recdev\/wp-json\/wp\/v2\/media?parent=11294"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}